iQ SERIES CABINETS
The iQ series 600mm and 800mm cabinet range is the most advanced Server Rack featured on the Australian market. A robust construction made from durable welded steel with powder coated finish gives the iQ series a variety of applications whether in a data centre or in a stand alone environment.
The extra width on the outside of the vertical mounting rails can also be utilised for cable management like the iQ Series Vertical Cable Management System. This is perfect for high density patching as it keeps all cable runs neat and manageable. The 600mm and 800mm wide Server Range is available in 38RU and 45RU configurations including 800mm, 900mm, 1000mm and 1200mm depths, so it will house most servers on the market today without overcrowding and allowing excellent air flow for maximum cooling of precious server hardware. The iQ series cabinet has been tested to 800kg’s UDL load rating and 1200kg without levelling feet.
The iQ Series has been designed so you can customise your data centre requirements by utilising a frame and modular system to bay cabinets together, as well as a large variety of door configurations including 3 Point Locking and Bi Fold designs.
BASIC FRAME INCLUSIONS
• Frame
• L rails (front and rear)
• RU labels (x4) - Front and Rear
• Levelling feet
OPTIONAL ACCESSORIES
• Monitored and switched PDU’s available with environmental sensors
• Super quiet whisper fans available as option
• Thermostat fan control system
• Power rails - horizontal/vertical
• IEC power rails available in 12 way and 20 way
• Fixed, sliding or keyboard shelves
• Sliding drawer
• Vertical/horizontal cable management solutions
• Fibre management trays
• Brushed plates
• Blank panels
| Part No. | Description |
| iQ3804 | 38RU 600 (w) x 800 (d) |
| iQ3810 | 38RU 600 (w) x 900 (d) |
| iQ3801 | 38RU 600 (w) x 1000 (d) |
| iQ3808 | 38RU 600 (w) x 1200 (d) |
| Part No. | Description |
| iQ3806 | 38RU 800 (w) 800 (d) |
| iQ3800 | 38RU 800 (w) 900 (d) |
| iQ3807 | 38RU 800 (w) 1000 (d) |
| iQ3809 | 38RU 800 (w) 1200 (d) |
| Part No. | Description |
| iQ4504 | 45RU 600 (w) x 800 (d) |
| iQ4510 | 45RU 600 (w) x 900 (d) |
| iQ4501 | 45RU 600 (w) x 1000 (d) |
| iQ4508 | 45RU 600 (w) x 1200 (d) |
| Part No. | Description |
| iQ4506 | 45RU 800 (w) x 800 (d) |
| iQ4500 | 45RU 800 (w) x 900 (d) |
| iQ4507 | 45RU 800 (w) x 1000 (d) |
| iQ4509 | 45RU 800 (w) x 1200 (d) |
SIDE, PRIVACY & ROOF PANELS
Side panels are used to totally enclose cabinets using locks provided. The panels sit flush with the cabinet when installed.
Privacy panels are used when baying cabinets together and a physical barrier is required between enclosures without the need for side panels. Privacy panels also prevent air leakage from one cabinet to another when bayed. Roof panels are made with provision for fan cooling and sit internally flush.
RAILS
L-Rails are fully adjustable to suit your requirements and are designed to accommodate most servers on the market. RU mounting holes are 9.5mm square and are designed for M6 cagenuts, and constructed from 2mm zinc annealed steel. RU labeling is pre-configured and supplied.
DOORS
Whether your Data Centre set up is hot isle/cold isle ceiling extraction or prefer a cold air plenum intake, we have a door solution to suit your requirement. There are six styles of doors available being acrylic, solid steel, perforated steel, perforated steel hi-flow, perforated steel bi-fold and perforated steel hi-flow bi-fold.
Doors are manufactured with hinges assembled on the right side of cabinet (viewing from the front) as standard. However cabinets can be manufactured with door hinges on the left - ensure that this is specified on your order.
ROOF CANOPY
Roof canopy’s are used when a hot ceiling plenum system is required - this helps direct heat through the chimney system.
PASSIVE COOLING SYSTEM
The Rack Technologies Passive Cooling Systems have been designed to maximise cooling within Data Centre environments while reducing energy consumption. The below unique design channels the cool air from the intake ducts at the base of the cabinet, and diverts the airflow to the front of the cabinet via adjustable vents. The vents can be opened or closed to direct the airflow to the designated hot spots within the cabinet.
This design incorporates solid front doors (steel or acrylic) to create a sealed cold air plenim.